Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Europace ; 25(6)2023 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-37294671

RESUMEN

AIMS: To define a stepwise application of left bundle branch pacing (LBBP) criteria that will simplify implantation and guarantee electrical resynchronization. Left bundle branch pacing has emerged as an alternative to biventricular pacing. However, a systematic stepwise criterion to ensure electrical resynchronization is lacking. METHODS AND RESULTS: A cohort of 24 patients from the LEVEL-AT trial (NCT04054895) who received LBBP and had electrocardiographic imaging (ECGI) at 45 days post-implant were included. The usefulness of ECG- and electrogram-based criteria to predict accurate electrical resynchronization with LBBP were analyzed. A two-step approach was developed. The gold standard used to confirm resynchronization was the change in ventricular activation pattern and shortening in left ventricular activation time, assessed by ECGI. Twenty-two (91.6%) patients showed electrical resynchronization on ECGI. All patients fulfilled pre-screwing requisites: lead in septal position in left-oblique projection and W paced morphology in V1. In the first step, presence of either right bundle branch conduction delay pattern (qR or rSR in V1) or left bundle branch capture Plus (QRS ≤120 ms) resulted in 95% sensitivity and 100% specificity to predict LBBP resynchronization, with an accuracy of 95.8%. In the second step, the presence of selective capture (100% specificity, only 41% sensitivity) or a spike-R <80 ms in non-selective capture (100% specificity, sensitivity 46%) ensured 100% accuracy to predict resynchronization with LBBP. CONCLUSION: Stepwise application of ECG and electrogram criteria may provide an accurate assessment of electrical resynchronization with LBBP (Graphical abstract).


Asunto(s)
Fascículo Atrioventricular , Terapia de Resincronización Cardíaca , Humanos , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/terapia , Estimulación Cardíaca Artificial/métodos , Terapia de Resincronización Cardíaca/métodos , Electrocardiografía/métodos , Sistema de Conducción Cardíaco , Resultado del Tratamiento
2.
JACC Clin Electrophysiol ; 8(11): 1431-1445, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36424012

RESUMEN

BACKGROUND: Conduction system pacing (CSP) has emerged as an alternative to biventricular pacing (BiVP). Randomized studies comparing both therapies are scarce and do not include left bundle branch pacing. OBJECTIVES: This study aims to compare ventricular resynchronization achieved by CSP vs BiVP in patients with cardiac resynchronization therapy indication. METHODS: LEVEL-AT (Left Ventricular Activation Time Shortening with Conduction System Pacing vs Biventricular Resynchronization Therapy) was a randomized, parallel, controlled, noninferiority trial. Seventy patients with cardiac resynchronization therapy indication were randomized 1:1 to BiVP or CSP, and followed up for 6 months. Crossover was allowed when primary allocation procedure failed. Primary endpoint was the change in left ventricular activation time, measured using electrocardiographic imaging. Secondary endpoints were left ventricular reverse remodeling and the combined endpoint of heart failure hospitalization or death at 6-month follow-up. RESULTS: Thirty-five patients were allocated to each group. Eight (23%) patients crossed over from CSP to BiVP; 2 patients (6%) crossed over from BiVP to CSP. Electrocardiographic imaging could not be performed in 2 patients in each group. A similar decrease in left ventricular activation time was achieved by CSP and BiVP (-28 ± 26 ms vs -21 ± 20 ms, respectively; mean difference -6.8 ms; 95% CI: -18.3 ms to 4.6 ms; P < 0.001 for noninferiority). Both groups showed a similar change in left ventricular end-systolic volume (-37 ± 59 mL CSP vs -30 ± 41 mL BiVP; mean difference: -8 mL; 95% CI: -33 mL to 17 mL; P = 0.04 for noninferiority) and similar rates of mortality or heart failure hospitalizations (2.9% vs 11.4%, respectively) (P = 0.002 for noninferiority). CONCLUSIONS: Similar degrees of cardiac resynchronization, ventricular reverse remodeling, and clinical outcomes were attained by CSP as compared to BiVP. CSP could be a feasible alternative to BiVP. (LEVEL-AT [Left Ventricular Activation Time Shortening With Conduction System Pacing vs Biventricular Resynchronization Therapy]; NCT04054895).


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/métodos , Sistema de Conducción Cardíaco , Bloqueo de Rama , Trastorno del Sistema de Conducción Cardíaco/terapia , Remodelación Ventricular
3.
Pacing Clin Electrophysiol ; 45(9): 1115-1123, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35583311

RESUMEN

BACKGROUND: It is unknown whether His-Purkinje conduction system pacing (HPCSP), as either His bundle or left bundle branch pacing, could be an alternative to cardiac resynchronization therapy (BiVCRT) for patients with left ventricular dysfunction needing ventricular pacing due to atrioventricular block. The aim of the study is to compare the echocardiographic response and clinical improvement between HPCSP and BiVCRT. METHODS: Consecutive patients who successfully received HPCSP were compared with a historical cohort of BiVCRT patients. Patients were 1:1 matched by age, LVEF, atrial fibrillation, renal function and cardiomyopathy type. Responders were defined as patients who survived, did not require heart transplantation and increased LVEF ≥5 points at 6-month follow-up. RESULTS: HPCSP was successfully achieved in 92.5% (25/27) of patients. During follow-up, 8% (2/25) of HPCSP patients died and 4% (1/25) received a heart transplant, whereas 4% (1/25) of those in the BiVCRT cohort died. LVEF improvement was 10% ± 8% HPCSP versus 7% ± 5% BiVCRT (p = .24), and the percentage of responders was 76% (19/25) HPCSP versus 64% (16/25) BiVCRT (p = .33). Among survivors, the percentage of patients who improved from baseline II-IV mitral regurgitation (MR) to 0-I MR was 9/11 (82%) versus 2/8 (25%) (p = .02). Compared to those with BiVCRT, patients with HPCSP achieved better NYHA improvement: 1 point versus 0.5 (OR 0.34; p = .02). CONCLUSION: HPCSP in patients with LVEF ≤45% and atrioventricular block improved the LVEF and induced a response similar to that of BiVCRT. HPCSP significantly improved MR and NYHA functional class. HPCSP may be an alternative to BiVCRT in these patients. (Figure 1. Central Illustration). [Figure: see text].


Asunto(s)
Bloqueo Atrioventricular , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Disfunción Ventricular , Fascículo Atrioventricular , Trastorno del Sistema de Conducción Cardíaco , Estimulación Cardíaca Artificial/efectos adversos , Terapia de Resincronización Cardíaca/efectos adversos , Insuficiencia Cardíaca/terapia , Humanos , Volumen Sistólico , Resultado del Tratamiento , Disfunción Ventricular/etiología , Disfunción Ventricular/terapia , Función Ventricular Izquierda
4.
Pacing Clin Electrophysiol ; 45(3): 374-383, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35015308

RESUMEN

BACKGROUND: His-Purkinje conduction system pacing (HPCSP) has been proposed as an alternative to Cardiac Resynchronization Therapy (CRT); however, predictors of echocardiographic response have not been described in this population. Septal flash (SF), a fast contraction and relaxation of the septum, is a marker of intraventricular dyssynchrony. METHODS: The study aimed to analyze whether HPCSP corrects SF in patients with CRT indication, and if correction of SF predicts echocardiographic response. This retrospective analysis of prospectively collected data included 30 patients. Left ventricular ejection fraction (LVEF) was measured with echocardiography at baseline and at 6-month follow-up. Echocardiographic response was defined as increase in five points in LVEF. RESULTS: HPCSP shortened QRS duration by 48 ± 21 ms and SF was significantly decreased (baseline 3.6 ± 2.2 mm vs. HPCSP 1.5 ± 1.5 mm p < .0001). At 6-month follow-up, mean LVEF improvement was 8.6% ± 8.7% and 64% of patients were responders. There was a significant correlation between SF correction and increased LVEF (r = .61, p = .004). A correction of ≥1.5 mm (baseline SF - paced SF) had a sensitivity of 81% and 80% specificity to predict echocardiographic response (area under the curve 0.856, p = .019). CONCLUSION: HPCSP improves intraventricular dyssynchrony and results in 64% echocardiographic responders at 6-month follow-up. Dyssynchrony improvement with SF correction may predict echocardiographic response at 6-month follow-up.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Disfunción Ventricular Izquierda , Estimulación Cardíaca Artificial , Terapia de Resincronización Cardíaca/métodos , Ecocardiografía , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos , Humanos , Estudios Retrospectivos , Volumen Sistólico/fisiología , Resultado del Tratamiento , Disfunción Ventricular Izquierda/prevención & control , Función Ventricular Izquierda
5.
JACC Clin Electrophysiol ; 7(11): 1400-1409, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34217660

RESUMEN

OBJECTIVES: This study hypothesized that the shorter intrinsic PR interval observed in women allows a greater degree of fusion with intrinsic conduction, achieving a shorter QRS interval duration and, thus, a better response. BACKGROUND: Women benefit more from cardiac resynchronization therapy (CRT) than men. However, the reason for this difference remains elusive. METHODS: A cohort of 180 patients included in the BEST (Fusion based optimization in resynchronization therapy [ECG Optimization of CRT: Evaluation of Mid-Term Response]; NCT01439529) study were retrospectively analyzed. Patients were initially randomized to either nonoptimized CRT (NON-OPT group; n = 89) or electrocardiographically optimized CRT based on the fusion-optimized intervals (FOI) method (FOI group; n = 91). Echocardiographic response was defined as a >15% decrease in left ventricular end-systolic volume at the 12-month follow-up. RESULTS: The basal PR interval was shorter in women as compared to men. In the NON-OPT group, CRT resulted in a shorter paced QRS interval in women than in men (134 ± 21 ms vs. 151 ± 21 ms, respectively; p = 0.003, 95% confidence interval [CI]: -27 to -5.6) and better response in women than in men: 70.4% vs. 46.4%, respectively (odds ratio: 0.37; p = 0.04; 95% CI: 0.14 to 0.97). There were no differences in paced QRS interval duration (126 ± 13 ms vs. 129 ± 17 ms; p = 0.47) or response between women and men in the FOI group (68% vs. 70.5%; odds ratio: 1.12; p = 0.82; 95% CI: 0.41 to 3.07). FOI extended the atrioventricular interval to obtain the best fusion; the atrioventricular intervals tended to require greater extension in men than in women (22 ± 33 ms vs. 8 ± 28 ms, respectively; p = 0.07). CONCLUSIONS: Women had a shorter PR interval, which was associated with a shorter QRS interval and better response to CRT. The difference in QRS interval duration and response between men and women did not persist when CRT was optimized using fusion with intrinsic conduction (FOI programming).


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Dispositivos de Terapia de Resincronización Cardíaca , Femenino , Insuficiencia Cardíaca/terapia , Frecuencia Cardíaca , Humanos , Masculino , Estudios Retrospectivos
6.
Pacing Clin Electrophysiol ; 44(3): 519-527, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33538337

RESUMEN

BACKGROUND: Multipoint pacing (MPP) in cardiac resynchronization therapy (CRT) activates the left ventricle from two locations, thereby shortening the QRS duration and enabling better resynchronization; however, compared with conventional CRT, MPP reduces battery longevity. On the other hand, electrocardiogram-based optimization using the fusion-optimized intervals (FOI) method achieves more significant reverse remodeling than nominal CRT programming. Our study aimed to determine whether MPP could attain better resynchronization than single-point pacing (SPP) optimized by FOI. METHODS: This prospective study included 32 consecutive patients who successfully received CRT devices with MPP capabilities. After implantation, the QRS duration was measured during intrinsic rhythm and with three pacing configurations: MPP, SPP-FOI, and MPP-FOI. In 14 patients, biventricular activation times (by electrocardiographic imaging, ECGI) were obtained during intrinsic rhythm and for each pacing configuration to validate the findings. Device battery longevity was estimated at the 45-day follow-up. RESULTS: The SPP-FOI method achieved greater QRS shortening than MPP (-56 ± 16 vs. -42 ± 17 ms, p < .001). Adding MPP to the best FOI programming did not result in further shortening (MPP-FOI: -58 ± 14 ms, p = .69). Although biventricular activation times did not differ significantly among the three pacing configurations, only the two FOI configurations achieved significant shortening compared with intrinsic rhythm. The estimated battery longevity was longer with SPP than with MPP (8.1 ± 2.3 vs. 6.3 ± 2.0 years, p = .03). CONCLUSIONS: SPP optimized by FOI resulted in better resynchronization and longer battery duration than MPP.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Disfunción Ventricular Izquierda/terapia , Anciano , Ecocardiografía , Suministros de Energía Eléctrica , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Disfunción Ventricular Izquierda/fisiopatología
7.
JACC Case Rep ; 2(14): 2225-2229, 2020 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-34317145

RESUMEN

His bundle pacing was developed while seeking a physiological alternative to biventricular cardiac resynchronization therapy. However, His bundle pacing may not be adequate in all patients. In this scenario, left bundle branch pacing has arisen as a new cardiac resynchronization therapy modality to correct left bundle branch block and restore ventricular synchrony. (Level of Difficulty: Intermediate.).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...